Skip to main content

Send Us a Message

Search

GrowoniX GXM-200-HF 200 GPD High Flow Replacement Membrane

Official GrowoniX Dealer Model: GOGXM-200-HF
starting from 0% interest financing from /mo.

Payment Options

Options:Pay in Four, Pay Monthly
Amount:Up to $1,500 (Pay in 4)
Up to $10,000 (Monthly)
Schedule:Bi-weekly to Monthly
Term:6 weeks, 12 or 24 months
Interest:0% to 35.99% APR*
Credit Check?Soft Check Only
Schedule:Bi-weekly to Monthly
Term:6 weeks, 6 or 12 months
Interest:0% to 35.99% APR*
Credit Check?Soft Check Only
Finance up to:$4,000
Must apply on a desktop device.
Schedule:Flexible
Term:Up to 36 months
Interest:Processing fee + interest
Lease-to-Own?Yes
Amount:$500 to $10,000
  • Delivers 200+ gallons per day of purified permeate
  • Maintains a consistent 2:1 ratio for efficient water usage
  • Fits standard 2 x 12 inch housings for direct compatibility
  • View More Details

Earn 111 points for shopping and get $1.11 off your next order. Join Harvest Club for free.

Questions? Talk to a specialist. Mon–Fri, 9am–5pm PST
Free Shipping On Most Items* To the lower 48
Transparent Pricing Backed w/ price match guarantee
1939+ Reviews 4.8/5 average
Secure Checkout SSL encrypted payments

Send Us a Message

VOLUME PRICING

Commercial & Bulk Purchasing

We support operations & licensed facilities with volume pricing, dedicated account managers, and custom equipment consultation.

Commercial Inquiry

Contact Information
THROUGH THE Cultivator's LENS Hands-On Evaluation

Who This Is For

  • You are replacing your RO membrane because your system flow rate is dropping and it is no longer meeting your daily water needs.
  • You are opting for the HF version because you need higher water volume output and can prioritize flow over the lowest possible TDS.

What We Found

  • We tell growers to stick with the HF model if their source water is cold because it maintains throughput better than standard elements.
  • This is a true drop-in replacement that takes about five minutes to swap without needing any tools or plumbing modifications.

What Users Say

  • Users who swapped to this membrane reported their systems returned to full output capacity within minutes of installation.
  • Operators in colder climates say they stopped seeing their production numbers crater during winter months after making the switch.

GrowoniX GXM-200-HF 200 GPD High Flow Replacement Membrane

When your RO system isn't keeping up with demand, the membrane is usually the first thing to check. The GrowoniX GXM-200-HF is the High Flow replacement membrane for the GX200, GX400, EX200, EX400, and EX400-T series systems — delivering 200+ gallons per day at a 2:1 waste ratio from a single 2" × 12" element. GrowoniX pioneered High Flow Cold Water membranes in the grow industry, and the GXM-200-HF continues that standard: maximum throughput, low TDS output, and consistent performance in cold water conditions where most membranes fall short.

The GXM-200-HF is a direct drop-in replacement — no tools, no modifications, no plumbing changes required. Simply swap out the spent element and restore your system to full rated output. For growers who prioritize flow rate and water production volume over the absolute lowest possible TDS, the HF version is the most popular choice in the GXM membrane lineup.

Features

💧
200+ GPD Single-Element Output

A single GXM-200-HF element produces 200+ gallons per day. If your source pressure is low, using a GrowoniX Booster Pump ensures you hit these rated flow targets in your GX or EX series system.

2:1 Waste Ratio

Operates at a 2:1 system ratio — two gallons of purified permeate produced for every one gallon discharged as waste, cutting water consumption compared to conventional RO membranes.

❄️
Cold Water Optimized

Engineered specifically for cold water performance — the GXM-200-HF maintains high flow and consistent TDS rejection in low-temperature source water conditions where standard membranes lose efficiency.

🏆
Industry-First HF Technology

GrowoniX introduced High Flow Cold Water membranes to the grow industry — the GXM-200-HF is the direct evolution of that technology, delivering unmatched throughput in its membrane class.

🔁
Wide System Compatibility

A direct drop-in fit for the GX150, GX200, GX300, GX400, EX200, EX400, and EX400-T — one membrane covering the full range of mid-size GrowoniX systems.

📐
2" × 12" Standard Form Factor

Sized to GrowoniX tolerances at 2" × 12" for a proper seal and consistent performance — installs directly into existing GX Series membrane housings without modification.

Specifications

Specification Value
Filter Size 2" × 12"
Membrane Flow Rate 200+ GPD
Membrane Version High Flow (HF)
System Ratio 2:1
Compatible Systems EX200, EX400, EX400-T, GX150, GX200, GX300, GX400

FAQs

Which GrowoniX systems is the GXM-200-HF compatible with? +

The GXM-200-HF is a direct drop-in replacement for the GX150, GX200, GX300, GX400, EX200, EX400, and EX400-T systems. It is not compatible with the larger GX1000 or EX1000 series housings — confirm your model against the compatibility list before ordering.

What is the difference between the HF and HR membrane versions? +

The High Flow (HF) version is optimized for maximum water production at 200+ GPD and is the most popular choice for most grow operations. The High Rejection (HR) version — such as the GXM-150-HR — produces a lower output TDS at a slightly reduced flow rate, making it the better fit when source water quality is poor and the purest possible permeate is the priority.

Why is the GXM-200-HF suited for cold water sources? +

Standard RO membranes lose flow rate and rejection efficiency as water temperature drops. The GXM-200-HF was engineered specifically for cold water performance, maintaining consistent output in low-temperature source water conditions — a common challenge in grow facilities sourcing cold municipal or well water.

How do I know when my membrane needs to be replaced? +

The two most reliable indicators are a measurable drop in system flow rate and a rise in output TDS compared to your post-installation baseline. If you're consistently seeing reduced production or permeate quality despite proper pre-filtration with a GrowoniX Sediment Filter and a GrowoniX Replacement Carbon filter, it is time to swap in a new membrane element.

Does the GXM-200-HF affect the system's waste ratio? +

The GXM-200-HF operates at a 2:1 waste ratio — the same ratio built into the GX Series system design. Replacing a spent membrane with a fresh GXM-200-HF restores the system to its rated efficiency without altering the plumbing configuration or waste output.

Should I flush the new membrane before putting it into service? +

Yes — flushing is required before collecting permeate water from a new membrane. New elements contain a preservation solution that must be fully purged at initial start-up. Use your GX Series manual flush valve to clear the membrane before beginning normal production.

Happy To Help

Questions About This Product?

Our specialists are happy to help. Call us or send a message and we'll get back to you within one business day (most of the time within a few hours.)

Call (360) 800-5535

Why Trimleaf

Equipping home growers, craft producers, and commercial operations across North America since 2016.

10+
Years of Specialist Knowledge
4.8★
Over 1,900 Verified Reviews
50,000+
Growers Served
120+
Top Equipment Brands in Stock