- 1 × AC Remote Station (ARS-1)
- 1 × Signal Emitter
- 1 × 16ft RJ12 Cable
- 1 × 4ft RJ12 Cable
- 1 × RJ12 T-Splitter
TrolMaster ARS-1 Mini-Split AC IR Remote Station
- Manages 1 mini-split unit by learning infrared commands from the factory remote
- On-board LCD screen allows for programming without a laptop
- Connects using standard RJ12 cables to Hydro-X and Tent-X systems
- 3-year warranty on all mechanical and electronic components
- View More Details
Earn 104 points for shopping and get $1.04 off your next order. Join Harvest Club for free.
Commercial & Bulk Purchasing
We support operations & licensed facilities with volume pricing, dedicated account managers, and custom equipment consultation.
Who This Is For
- You are automating your climate cycles because manually adjusting your mini-split remote is keeping you from the canopy.
- You are adding IR control because your AC unit lacks a hardwired port for direct connection to your main controller.
What We Found
- IR emitter placement is everything since even a tiny obstruction prevents the station from talking to your AC.
- Keep a Micro-SD card handy since firmware updates are the only way to add support for newer mini-split brands.
What Users Say
- Users who automated their cooling say they stopped checking their rooms at night once the ARS-1 took over the remote.
- Commercial operators report that assigning individual unit addresses made balancing temps across zones much easier.
TrolMaster ARS-1 Mini-Split AC IR Remote Station
Managing the temperature in your grow room shouldn't require constant manual intervention. While mini-split AC units are powerful climate tools, their reliance on handheld remotes often leaves a gap in automation. The TrolMaster ARS-1 AC Remote Station bridges this gap by learning the IR commands from your existing remote, allowing your climate controller to take full command of your cooling and heating cycles.
By integrating the ARS-1 with your TrolMaster Hydro-X HCS-1 Grow Tent Control or Tent-X system, you can eliminate manual adjustments forever. Once the signal emitter is positioned and programmed, the system automatically sends commands based on your precise environmental setpoints. With a simple setup process and a Micro-SD slot for future firmware updates, the ARS-1 is the ultimate solution for professional mini-split automation.
Compatibility: TrolMaster Hydro-X and Tent-X Systems | IR Remote-Controlled Mini-Split AC Units
What's Included
Features
IR Mini-Split Control
Learns IR commands directly from your existing remote to bring any compatible mini-split under automation.
LCD Display & Easy Setup
The built-in LCD screen guides you through a straightforward programming process that takes only minutes.
Address Assignment
Individually identify the ARS-1 within your TrolMaster network for precise control in multi-unit grow environments.
Micro-SD Updates
Stay current with the latest AC compatibility and features via the integrated Micro-SD firmware slot.
Plug & Play Design
Comes complete with RJ12 cables, T-splitter, and signal emitter for immediate installation out of the box.
TrolMaster ARS-1 Specifications
| Specification | Value |
|---|---|
| Output Voltage | 24V |
| Maximum Current | 1A |
| Firmware Updates | Micro-SD slot |
| Working Environment | Temperature 32–122°F (0–50°C), Humidity ≤90% |
| Package Dimensions | 160mm (L) × 86mm (W) × 86mm (H) |
| Gross Weight | 0.43 kg |
| Compatibility | TrolMaster Hydro-X, Tent-X |
Support & Manuals
Warranty
TrolMaster provides a 3-year warranty for the ARS-1 from the original date of purchase. This warranty covers all mechanical and electronic components under normal operating conditions. Damage resulting from improper use or abnormal conditions is not covered.
FAQs
The ARS-1 is designed to work with any AC unit that utilizes an infrared (IR) remote. By learning the signals from your existing remote, it can control the majority of mini-split and window-style units on the market.
The ARS-1 controls a single operating mode learned from your remote. The ARS-2 is an advanced version that can manage multiple modes (Cool, Heat, Auto) and is compatible with a wider range of controllers, including the HCS series.
Programming is done directly on the ARS-1 using its LCD screen. You simply point your AC remote at the station and follow the prompts to record the on, off, and temperature signals.
The emitter should be placed with a clear line of sight to the IR receiver on your AC unit. If the unit is mounted far away, an extension cable (ECS-8) may be required.
Firmware updates are performed using the built-in Micro-SD slot. Download the latest firmware from TrolMaster, save it to a card, and insert it into the ARS-1 following the update guide instructions.
Questions About This Product?
Our specialists are happy to help. Call us or send a message and we'll get back to you within one business day (most of the time within a few hours.)
Why Trimleaf
Equipping home growers, craft producers, and commercial operations across North America since 2016.