  • 1000 GPD rated membrane capacity
  • High Rejection version for elevated purity
  • Direct drop in replacement for EX1000 and GX1000 housings
  • View More Details
Special Order: Please Contact Us for Availability

Earn 449 points for shopping and get $4.49 off your next order. Join Harvest Club for free.

Questions? Talk to a specialist. Mon–Fri, 9am–5pm PST
Free Shipping On Most Items* To the lower 48
Transparent Pricing Backed w/ price match guarantee
Secure Checkout SSL encrypted payments

Send Us a Message

Ask Sage about this product
VOLUME PRICING

Commercial & Bulk Purchasing

We support operations & licensed facilities with volume pricing, dedicated account managers, and custom equipment consultation.

Commercial Inquiry

Contact Information
THROUGH THE Cultivator's LENS Hands-On Evaluation

  • You are scaling up daily pure water production to 1000 GPD because your current filtration capacity cannot keep pace with your facility demand
  • You are treating high TDS source water because standard reverse osmosis elements fail to hit the low parts per million baseline your nutrients require

  • The high rejection version trades a modest flow reduction for elevated purity output
  • The 4 by 21 inch form factor seats directly into existing housings without plumbing changes

  • Growers running high TDS source water say this high rejection element dropped their output parts per million low enough to maintain strict nutrient precision
  • Operators servicing EX and GX series housings report that the drop in replacement design allowed a fast swap without altering existing plumbing lines

GrowoniX GXM-1000 HR 1000 GPD Replacement RM Membrane (Special Order Only)

When output purity matters more than raw flow rate, the GrowoniX GXM-1000 HR is the right membrane for the job. This High Rejection version of the GXM-1000 is engineered to deliver ultra-high TDS rejection — producing the cleanest possible permeate from your GX1000 or EX1000 series system. It's the preferred choice for growers working with higher-TDS source water or in applications where every point of reduction in output TDS has a direct impact on crop quality and nutrient precision.

The GXM-1000 HR is a direct drop-in replacement membrane for the EX1000, EX1000-T, and GX1000 series housings — no tools or modifications required. At 4" × 21", it seats into the existing GX Series membrane housing and restores system performance without any plumbing changes. Note that flow rate data published by GrowoniX is based on the High Flow (HF) element; the HR version trades a modest reduction in GPD output for its elevated rejection performance. 

Features

⚗️
Ultra High TDS Rejection

The HR element is optimized for the highest possible rejection rate, producing the cleanest permeate water available from a GX Series system — ideal for sensitive applications and high-TDS source water.

💧
1000 GPD Rated Capacity

Rated at 1000 GPD to maintain high-volume water production, with the HR version delivering slightly reduced flow compared to the HF element in exchange for superior purity output.

🔁
Direct Drop-In Replacement

Sized at 4" × 21" to seat directly into EX1000, EX1000-T, and GX1000 housings with no modifications, tools, or plumbing changes required.

📐
4" × 21" Industry-Standard Size

Standard 4" × 21" form factor engineered to GrowoniX tolerances for a proper seal and consistent performance inside the GX Series membrane housing.

Specifications

Specification Value
Filter Size 4" × 21"
Membrane Flow Rate 1000 GPD
Membrane Version High Rejection (HR)
Compatible Systems EX1000, EX1000-T, GX1000
Availability Special Order

FAQs

What makes the HR version different from the High Flow (HF) membrane? +

The High Rejection (HR) membrane is engineered specifically for the lowest possible output TDS, making it the right choice when water purity is the top priority. Compared to the High Flow (HF) version, the HR element delivers a slightly lower GPD flow rate in exchange for its elevated rejection performance — ideal for high-TDS source water or applications requiring the cleanest possible permeate.

Which systems is the GXM-1000 HR compatible with? +

The GXM-1000 HR fits directly into the EX1000, EX1000-T, and GX1000 reverse osmosis systems. It is not interchangeable with smaller GX Series membrane housings — refer to GrowoniX's Filter Replacement Guide to confirm compatibility with your specific model before ordering.

What does "Special Order" mean, and how long does it take to ship? +

Special Order items are not stocked on-hand and are sourced directly from the manufacturer upon purchase. Lead times vary — contact us before ordering if you have a time-sensitive need and we'll provide an estimated availability window.

How do I know when it's time to replace my membrane? +

The most reliable indicators are a measurable drop in system flow rate or a rise in output TDS compared to your baseline readings after initial installation. To maintain optimal pressure and performance, ensure your system is utilizing a compatible GrowoniX BP-1000 HF Adjustable Booster Pump. Regular membrane flushing will extend service life, but consistent degradation in performance is a clear signal that replacement is due.

Does installing the HR membrane affect the system's 2:1 waste ratio? +

No — the 2:1 waste ratio is determined by the GX Series system design and plumbing configuration, not the membrane version installed. Switching from HF to HR affects output flow rate and permeate TDS only; the overall system efficiency and waste ratio remain the same.

Should I flush the membrane before putting it into service? +

Yes — flushing a new membrane at initial start-up is strongly recommended. New elements contain a preservation solution that must be purged before collecting permeate water for use. Use the GX Series manual flush valve to clear the membrane and bring the system up to full operating performance before normal production begins.

Happy To Help

Questions About This Product?

Our specialists are happy to help. Call us or send a message and we'll get back to you within one business day (most of the time within a few hours.)

Call (360) 800-5535

Why Trimleaf

Equipping home growers, craft producers, and commercial operations across North America since 2016.

10+
Years of Specialist Knowledge
4.8★
2000+ Verified Reviews
50,000+
Growers Served
120+
Top Equipment Brands in Stock