{"product_id":"anden-a711-v3-commercial-dehumidifier-705-ppd-277v","title":"Anden A711 V3 Dehumidifier — 705 Pints\/Day","description":"\u003ch4\u003e\u003c\/h4\u003e\u003ch2\u003eAnden A711 V3 Dehumidifier — 705 Pints\/Day\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eCommercial facilities wired for 277V need dehumidification that runs on their existing power without step-down transformers or extra circuits. The Anden A711 V3 removes up to 705 pints per day (at 80°F, 60% RH) and moves 1,800 CFM on 277V single-phase power, drawing just 13.7 amps at rated conditions.\u003c\/p\u003e\n\u003cp\u003eThe A711 V3 is built around M-CORR (Multi-Coil Refrigerant Recovery), patented technology developed by the engineers behind Quest. It optimizes multiple coils and recycles refrigerant through the system, which raises efficiency and extends operation across a broader dewpoint range than a standard two-coil dehumidifier. In late flower, when transpiration peaks and many units lose time to defrost cycles, the A711 V3 keeps pulling water. That helps hold humidity and VPD steady to support plant health and crop quality.\u003c\/p\u003e\n\u003cp\u003eThe A711 V3 sticks to the essentials growers rely on and keeps upfront cost in check. Integrated suspension points, a ductable cabinet, a removable cord for hardwiring, a digital interface with onboard error codes, a 24VAC terminal block for external controllers, and a removable service panel keep installation and maintenance simple. For 208-240V facilities, the same platform is available as the \u003ca href=\"\/products\/anden-a711-v1-grow-room-dehumidifier-705-ppd-240v\" style=\"color:#2c5530;\"\u003eAnden A711 V1\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cstyle\u003e\n  .features-grid-container{display:flex;flex-wrap:wrap;justify-content:center;gap:1rem;padding:2rem 0;font-family:'Helvetica Neue',Helvetica,Arial,sans-serif;margin:0 auto;max-width:1240px;}\n  .feature-card{background-color:transparent;padding:1.5rem;border-radius:8px;text-align:center;flex:0 1 240px;box-sizing:border-box;}\n\u003c\/style\u003e\n\u003cdiv class=\"features-grid-container\"\u003e\n    \u003cdiv class=\"feature-card\"\u003e\n      \u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e⚡\u003c\/span\u003e\n      \u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eNative 277V Power\u003c\/h5\u003e\n      \u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eRuns on 277V single-phase service at 13.7 amps with no step-down transformer required.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"feature-card\"\u003e\n      \u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e💧\u003c\/span\u003e\n      \u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003e705 Pints Per Day\u003c\/h5\u003e\n      \u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eHandles heavy moisture loads in large flower rooms, with 7.6 pints\/kWh efficiency at rated conditions.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"feature-card\"\u003e\n      \u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e❄️\u003c\/span\u003e\n      \u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eM-CORR Technology\u003c\/h5\u003e\n      \u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eMulti-coil refrigerant recovery extends the dewpoint range and cuts time lost to defrost.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"feature-card\"\u003e\n      \u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🏗️\u003c\/span\u003e\n      \u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eHang, Stand, or Duct\u003c\/h5\u003e\n      \u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eSuspend overhead, place on the floor, or duct from an adjacent room. The cord is removable for hardwiring.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"feature-card\"\u003e\n      \u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🎛️\u003c\/span\u003e\n      \u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eDigital and Remote Control\u003c\/h5\u003e\n      \u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eSet RH onboard, read error codes, or connect an external controller through the 24VAC terminal block.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"feature-card\"\u003e\n      \u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🔧\u003c\/span\u003e\n      \u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eEasy Filters and Service\u003c\/h5\u003e\n      \u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eSelf-sealing MERV-13 filters pull straight out, and a removable side panel opens up in-place service.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eWhat's Included\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eAnden A711 V3 Dehumidifier\u003c\/li\u003e\n  \u003cli\u003eLeveling feet\u003c\/li\u003e\n  \u003cli\u003eCondensate hose\u003c\/li\u003e\n  \u003cli\u003eBarb fitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4 style=\"margin-bottom: 0;\"\u003eSpecifications\u003c\/h4\u003e\n\u003cstyle\u003e.styled-spec-container{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;border:1px solid #eee;border-radius:8px;margin-bottom:1em;}.styled-spec-table{width:100%;border-collapse:collapse;}.styled-spec-table thead{background-color:#f8f8f8;}.styled-spec-table th,.styled-spec-table td{padding:12px 15px;text-align:left;vertical-align:top;}.styled-spec-table th{font-weight:bold;color:#333;border-bottom:2px solid #ccc;}.styled-spec-table td{border-bottom:1px solid #eee;}.styled-spec-table tbody td:first-child{font-weight:500;color:#444;}.styled-spec-table tbody tr:last-child td{border-bottom:none;}\u003c\/style\u003e\n\u003cdiv class=\"styled-spec-container\"\u003e\n  \u003ctable class=\"styled-spec-table\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003cth\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e705 pints\/day @ 80°F, 60% RH\u003cbr\u003e471 pints\/day @ 75°F, 50% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eEnergy Factor\u003c\/td\u003e\n\u003ctd\u003e7.6 pints\/kWh (3.6 L\/kWh) @ 80°F, 60% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003e1,800 CFM @ 0.0\" WG\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase \/ Frequency\u003c\/td\u003e\n\u003ctd\u003e277V, Single Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e13.7 A @ 80°F, 60% RH\u003cbr\u003e12.7 A @ 75°F, 50% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e3,740 W\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003eNEMA L7-20P, 6 ft. (removable for hardwiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e21 A \/ 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e56°F \/ 40% RH to 95°F \/ 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOnboard digital interface with low-voltage terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eAir Filter\u003c\/td\u003e\n\u003ctd\u003eMERV-13, 18\" × 20\" × 2\" (2 required)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR454B, 100 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDrain Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4\" FNPT (P-trap required)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e44.7\" × 29\" × 27.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eInstallation Options\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo two cultivation rooms are laid out the same. The Anden A711 V3 supports three installation methods, so you can fit it to your space instead of redesigning the room around it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin: 20px 0;\"\u003e\n  \u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n    \u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\n      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A711_V1_Dehumidifer_2.png?v=1792683454\" alt=\"Anden A711 V3 Dehumidifier suspended from ceiling with threaded rods\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\n    \u003c\/div\u003e\n    \u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eSuspended\u003c\/h5\u003e\n    \u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eMounts above the lights to save floor space without blocking light.\u003c\/p\u003e\n    \u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n      \u003cli\u003eBuilt-in suspension points accept 3\/8\" threaded rod\u003c\/li\u003e\n      \u003cli\u003ePulls in humid air and returns dry air to the room\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n    \u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\n      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A711_V1_Dehumidifer_3.png?v=1792683454\" alt=\"Anden A711 V3 Dehumidifier freestanding on leveling feet with condensate drain\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\n    \u003c\/div\u003e\n    \u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eFreestanding\u003c\/h5\u003e\n    \u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eSits on the floor inside the cultivation room.\u003c\/p\u003e\n    \u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n      \u003cli\u003eIdeal where overhead mounting isn't possible\u003c\/li\u003e\n      \u003cli\u003eIncluded adjustable feet level the unit on flat surfaces\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n    \u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\n      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A711_V1_Dehumidifer_4.jpg?v=1792683453\" alt=\"Anden A711 V3 Dehumidifier with inlet and outlet duct connections\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\n    \u003c\/div\u003e\n    \u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eInlet and Outlet Ducted\u003c\/h5\u003e\n    \u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eInstalls in a separate room and connects to the grow space through ducts.\u003c\/p\u003e\n    \u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n      \u003cli\u003eIdeal for grows with no space for an in-room unit\u003c\/li\u003e\n      \u003cli\u003eCan be suspended or installed at ground level\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSupport \u0026amp; Manuals\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-TS-2206-A711-Manual.pdf?v=1792683252\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\n\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eInstallation \u0026amp; Operating Manual\u003c\/span\u003e\n\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-A711-V3-Spec-Sheet.pdf?v=1792683844\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\n\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\n\u003cspan style=\"font-weight: bold;\"\u003eA711 V3 Spec Sheet\u003c\/span\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eWarranty\u003c\/h4\u003e\n\u003cp\u003eThe Anden A711 V3 Dehumidifier is covered by a 3-year limited manufacturer warranty from the original date of purchase.\u003c\/p\u003e\n\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cdiv class=\"faq-container\"\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat's the difference between the A711 V3 and the A711 V1?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eBoth models share the same 705 pints\/day capacity, 1,800 CFM airflow, M-CORR coil design, and cabinet. The A711 V3 is built for 277V single-phase power with an MCA of 21 A and MOP of 30 A. The A711 V1 runs on 208-240V. Choose the model that matches the electrical service in your facility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat receptacle and circuit does the A711 V3 need?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A711 V3 ships with a 6 ft. NEMA L7 twist-lock cord and runs on a 277V single-phase circuit sized to its 21 A MCA and 30 A MOP. A GFCI-protected circuit is recommended, and the unit should never be used with an extension cord. The cord can also be removed for hardwiring with a field-installed disconnect.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eHow many A711 V3 units can I run from one controller?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eUp to six units can be daisy-chained to a single external control. Because every unit starts at once, monitor supply voltage at startup: on 277V models it should not drop below 250V. If it does, add controllers or use time-delay relays to stagger startup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eCan I daisy-chain the A711 V3 with older Anden A710 units?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes, but the A711 must be placed last in the chain. Wiring it ahead of A710 units can damage the units downstream. Refer to the daisy chain diagrams in the installation manual before wiring a mixed setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhich external controllers work with the A711 V3?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eAnden's DEH 3000R and QA76 controls connect directly to the 24VAC terminal block, as does any dry-contact controller rated for a 24VAC signal, such as TrolMaster. After wiring, press the Terminal Control button so the unit follows the external signal instead of its internal RH sensor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat do I need to hang or duct the A711 V3?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eTo hang the unit, you'll need four 3\/8\" threaded rods and four 3\/8\" jam nuts (not included), with a maximum rod length of 6 ft. For ducted installs, use the optional intake and exhaust duct kits with at least two 15\" round ducts, and keep static pressure under 0.25\" WG.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat do the error codes on the display mean?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe onboard display shows codes E1 through E9 to flag issues such as a sensor fault, low dewpoint, low refrigerant, a tripped float switch, or high-pressure cut-out. Many codes clear on their own once conditions return to range. Codes like E3 (low refrigerant) and E4 (float switch tripped) require service. The full error code table is in the installation manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat does the A711 V3 warranty cover?\u003c\/span\u003e\n\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe 3-year limited warranty includes 1 year of full coverage, plus 2 additional years of parts replacement on the condenser, evaporator, and compressor. Running the unit without its MERV-13 filters, or with a lower-grade filter, voids the warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Anden","offers":[{"title":"Default Title","offer_id":52771651944664,"sku":"A711V3","price":10999.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A711_V3_Dehumidifer_1.png?v=1792683908","url":"https:\/\/trimleaf.com\/products\/anden-a711-v3-commercial-dehumidifier-705-ppd-277v","provider":"Trimleaf","version":"1.0","type":"link"}