{"product_id":"anden-a321-v3-commercial-grow-dehumidifier-320-ppd-277v","title":"Anden A321 V3 Dehumidifier — 320 Pints\/Day","description":"\u003ch4\u003e\u003c\/h4\u003e\u003ch2\u003eAnden A321 V3 Dehumidifier — 320 Pints\/Day\u003c\/h2\u003e\u003cdiv\u003e\n\u003cp\u003eCommercial buildings wired for 277V often end up running step-down transformers or extra circuits just to power standard 240V grow equipment. The Anden A321 V3 skips that step. It runs directly on 277V single-phase power, removes up to 320 pints of water per day (at 80°F, 60% RH), and draws only 7.2 amps at rated conditions. For larger scale moisture removal, our \u003ca href=\"\/products\/anden-a711-v3-commercial-dehumidifier-705-ppd-277v\" style=\"color:#2c5530;\"\u003eAnden A711 V3 Dehumidifier\u003c\/a\u003e delivers 705 pints per day on the same 277V power, while for smaller grow spaces, the \u003ca href=\"\/products\/anden-a210v1-dehumidifier\" style=\"color:#2c5530;\"\u003eAnden A210 V1 Dehumidifier\u003c\/a\u003e offers a compact 210 pints of daily capacity.\u003c\/p\u003e\n\u003cp\u003eThe A321 V3 is built to keep relative humidity under 60%, the point where mold and mildew risk climbs and plants lose the stomatal activity they need to take in CO2. It moves 775 CFM through the room and holds your setpoint with an onboard digital control that also displays self-diagnostic error codes. A 24VAC terminal block connects to external controllers, including multi-unit daisy chains. Beyond dehumidification, we support complete climate control; for facilities needing to add moisture, explore our \u003ca href=\"\/products\/anden-as35fp-medium-capacity-steam-humidifier\" style=\"color:#2c5530;\"\u003eAnden AS35FP\u003c\/a\u003e and \u003ca href=\"\/products\/anden-as150-high-capacity-steam-humidifier\" style=\"color:#2c5530;\"\u003eAnden AS150\u003c\/a\u003e steam humidifiers, which pair perfectly with the \u003ca href=\"\/products\/anden-a65-humidifier-control-for-as35fp\" style=\"color:#2c5530;\"\u003eAnden A65 Humidifier Control\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eInstallation is just as flexible as the power is convenient. Built-in 3\/8\" threaded inserts let you hang the unit without a separate kit, leveling feet handle freestanding setups, and an optional duct kit supports remote installs. The A321 V3 is designed and assembled in the USA and backed by a 3-year limited warranty. For 208-240V facilities, the same platform is available as the \u003ca href=\"\/products\/anden-a321-v1-mid-size-grow-dehumidifier-320-ppd-240v\" style=\"color:#2c5530;\"\u003eAnden A321 V1\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch4\u003eFeatures\u003c\/h4\u003e\u003cstyle\u003e.features-grid-container{display:flex;flex-wrap:wrap;justify-content:center;gap:1rem;padding:2rem 0;font-family:'Helvetica Neue',Helvetica,Arial,sans-serif;margin:0 auto;max-width:1240px;}.feature-card{background-color:transparent;padding:1.5rem;border-radius:8px;text-align:center;flex:0 1 240px;box-sizing:border-box;}\u003c\/style\u003e\u003cdiv class=\"features-grid-container\"\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e⚡\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eDirect 277V Operation\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eRuns on 277V commercial power at just 7.2 amps, with no step-down transformer needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e💧\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003e320 Pints Per Day\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003ePulls heavy transpiration loads with 6.8 pints\/kWh efficiency at 80°F, 60% RH.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🌀\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003e775 CFM Circulation\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eKeeps air moving through the room for more even humidity across the canopy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🔩\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eIntegrated Hang Points\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eBuilt-in rivet nuts take standard 3\/8\" threaded rod, so there's no extra hang kit to buy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🎛️\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eOnboard and Remote Control\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eA digital interface with error codes, plus a 24VAC terminal block for external controllers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🔧\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eEasy Service and Filters\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eA removable side panel and a self-sealing MERV-13 filter keep maintenance quick.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch4\u003eWhat's Included\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAnden A321 V3 Dehumidifier\u003c\/li\u003e\n\u003cli\u003eLeveling feet\u003c\/li\u003e\n\u003cli\u003eCondensate hose\u003c\/li\u003e\n\u003cli\u003eBarb fitting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 style=\"margin-bottom: 0;\"\u003eSpecifications\u003c\/h4\u003e\u003cstyle\u003e.styled-spec-container{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;border:1px solid #eee;border-radius:8px;margin-bottom:1em;}.styled-spec-table{width:100%;border-collapse:collapse;}.styled-spec-table thead{background-color:#f8f8f8;}.styled-spec-table th,.styled-spec-table td{padding:12px 15px;text-align:left;vertical-align:top;}.styled-spec-table th{font-weight:bold;color:#333;border-bottom:2px solid #ccc;}.styled-spec-table td{border-bottom:1px solid #eee;}.styled-spec-table tbody td:first-child{font-weight:500;color:#444;}.styled-spec-table tbody tr:last-child td{border-bottom:none;}\u003c\/style\u003e\u003cdiv class=\"styled-spec-container\"\u003e\u003ctable class=\"styled-spec-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e320 pints\/day @ 80°F, 60% RH\u003cbr\u003e240 pints\/day @ 75°F, 50% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Factor\u003c\/td\u003e\n\u003ctd\u003e6.8 pints\/kWh (3.2 L\/kWh) @ 80°F, 60% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003e775 CFM @ 0.0\" WG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase \/ Frequency\u003c\/td\u003e\n\u003ctd\u003e277V, Single Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e7.2 A @ 80°F, 60% RH\u003cbr\u003e6.5 A @ 75°F, 50% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1,930 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003eNEMA L7-15P, 6 ft. (removable for hardwiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e56°F \/ 40% RH to 95°F \/ 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOnboard digital interface with low-voltage terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Filter\u003c\/td\u003e\n\u003ctd\u003eMERV-13, 20\" × 22\" × 2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR454B, 62 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4\" FNPT (P-trap required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e32.9\" × 24.6\" × 23.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e178 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch4\u003eInstallation Options\u003c\/h4\u003e\u003cdiv\u003e\u003cp\u003eCommercial grow spaces rarely share the same layout. The Anden A321 V3 can be hung, set on the floor, or ducted from another room to match the space you have.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin: 20px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n\u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_1.png?v=1792684234\" alt=\"Anden A321 V3 Dehumidifier suspended from ceiling with threaded rods\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\u003c\/div\u003e\n\u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eSuspended\u003c\/h5\u003e\n\u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eMounts overhead to free up floor space in the cultivation room.\u003c\/p\u003e\n\u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n\u003cli\u003eBuilt-in threaded inserts accept 3\/8\" threaded rod\u003c\/li\u003e\n\u003cli\u003eNo separate hang kit required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n\u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_2.png?v=1792684235\" alt=\"Anden A321 V3 Dehumidifier freestanding on a raised platform\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\u003c\/div\u003e\n\u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eFreestanding\u003c\/h5\u003e\n\u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eOperates on the floor inside the grow room.\u003c\/p\u003e\n\u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n\u003cli\u003eIncluded leveling feet steady the unit on uneven floors\u003c\/li\u003e\n\u003cli\u003eRaise the base 6\" so a P-trap fits below the drain\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n\u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_3.png?v=1792684234\" alt=\"Anden A321 V3 Dehumidifier with inlet and outlet duct connections\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\u003c\/div\u003e\n\u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eInlet and Outlet Ducted\u003c\/h5\u003e\n\u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eSits in an adjacent room and connects to the grow space through ducts.\u003c\/p\u003e\n\u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n\u003cli\u003eIdeal where in-room space is limited\u003c\/li\u003e\n\u003cli\u003eOptional duct kit sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch4\u003eSupport \u0026amp; Manuals\u003c\/h4\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-Manual-A321.pdf?v=1792684158\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eInstallation \u0026amp; Operating Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-Spec-Sheet-A321v3.pdf?v=1792684551\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eA321 V3 Spec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-A320-to-321-Transition.pdf?v=1792684158\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eA320 to A321 Transition Guide\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003cp\u003eThe Anden A321 V3 Dehumidifier is covered by a 3-year limited manufacturer warranty from the original date of purchase.\u003c\/p\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cdiv class=\"faq-container\"\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eHow is the A321 V3 different from the A321 V1?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eBoth share the same 320 pints\/day capacity, 775 CFM airflow, cabinet, and controls. The A321 V3 runs on 277V single-phase power with a NEMA L7-15P twist-lock cord and draws 7.2 A. The A321 V1 runs on 208-240V with a NEMA 6-15P cord. Match the model to your facility's electrical service.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat circuit does the A321 V3 require?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe A321 V3 needs a 277V single-phase circuit with an L7-15R twist-lock receptacle, sized to its 15 A MCA. A GFCI-protected circuit is required. For hardwired installs, swap the cord for the jumper wires in the packed parts kit and add a field-installed disconnect.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eI'm replacing a 277V Anden A320. Can I keep my existing receptacle?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe A320 used a 20A L7-20 cord, while the A321 V3 ships with a 15A L7-15 cord. The plugs are not interchangeable. Anden's transition guide shows how to move the A320's 20A cord into the A321 V3 so it fits your existing L7-20R outlet. The guide also covers updated hanging points, drain trap setup, and the A77 controller, which does not work directly with the A321.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eHow do I suspend the A321 V3?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eUse four 3\/8\" threaded rods in the built-in rivet nuts on top, which are spaced 16.6\" × 22.2\" apart. Thread each rod in 1.5\"-2.5\" (going deeper can damage the unit), and never hang the unit from its sides or ends. Mount it so the drain outlet sits 6.75\" above the floor drain to leave room for the P-trap.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eCan I run several A321 V3 units from one controller?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eYes. Up to six units can be daisy-chained to one DEH 3000R, QA76, or other 24VAC dry-contact controller. Every unit starts at once, so check that supply voltage stays above 250V at startup. If it dips, add controllers or use time-delay relays. When mixing with A320 units, the A321 must be last in the chain.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eCan the A321 V3 be installed outside the grow room?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eYes. With the optional duct kit, sold separately, the A321 V3 can sit in an adjacent room and connect to the grow space through intake and supply ducts. Keep static pressure under 0.25\" WG, and duct directly to the room rather than through open plenums like drop ceilings.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat does the A321 V3 warranty cover?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe 3-year limited warranty includes 1 year of full coverage, plus 2 additional years of parts replacement on the condenser, evaporator, and compressor. For a claim, call the factory first at 1-877-420-1330 for authorization.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Anden","offers":[{"title":"Default Title","offer_id":52771683139800,"sku":"A321V3","price":4499.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V3_Dehumidifer_1.png?v=1792684610","url":"https:\/\/trimleaf.com\/products\/anden-a321-v3-commercial-grow-dehumidifier-320-ppd-277v","provider":"Trimleaf","version":"1.0","type":"link"}