{"product_id":"anden-a321-v1-mid-size-grow-dehumidifier-320-ppd-240v","title":"Anden A321 V1 Dehumidifier — 320 Pints\/Day","description":"\u003ch4\u003e\u003c\/h4\u003e\u003ch2\u003eAnden A321 V1 Dehumidifier — 320 Pints\/Day\u003c\/h2\u003e\u003cdiv\u003e\n\u003cp\u003eMold, mildew, and stalled photosynthesis all start when grow room humidity creeps above 60%. In a mid-size flowering room, transpiration alone can push it there within hours of lights-on. The Anden A321 V1 removes up to 320 pints of water per day (at 80°F, 60% RH) and moves 775 CFM through the canopy on standard 208-240V power. It's built to hold your setpoint through every stage of growth. If your space is smaller, the \u003ca href=\"\/products\/anden-a210v1-dehumidifier\"\u003eAnden A210 V1\u003c\/a\u003e offers similar high-quality dehumidification in a more compact package, while larger operations can utilize the \u003ca href=\"\/products\/anden-a711-v1-grow-room-dehumidifier-705-ppd-240v\"\u003eAnden A711 V1\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eThe A321 V1 is designed and assembled in the USA specifically for cultivation. Its onboard digital control sets and holds RH, displays self-diagnostic error codes, and includes a low-voltage terminal block for remote controllers. Built-in 3\/8\" threaded inserts let you hang the unit without a separate hang kit, and the pre-installed plug comes out for hardwired installs.\u003c\/p\u003e\n\u003cp\u003eThe A321 V1 can be suspended above the lights, set on the floor, or ducted in from an adjacent room, so it fits your layout instead of dictating it. A self-sealing MERV-13 filter protects the coils and pulls straight out for replacement. Growers upgrading from an Anden A320 can use the included transition guide for wiring, cord, and mounting changes. For 277V facilities, the \u003ca href=\"\/products\/anden-a321-v3-commercial-grow-dehumidifier-320-ppd-277v\"\u003eAnden A321 V3\u003c\/a\u003e is also available.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch4\u003eFeatures\u003c\/h4\u003e\u003cstyle\u003e.features-grid-container{display:flex;flex-wrap:wrap;justify-content:center;gap:1rem;padding:2rem 0;font-family:'Helvetica Neue',Helvetica,Arial,sans-serif;margin:0 auto;max-width:1240px;}.feature-card{background-color:transparent;padding:1.5rem;border-radius:8px;text-align:center;flex:0 1 240px;box-sizing:border-box;}\u003c\/style\u003e\u003cdiv class=\"features-grid-container\"\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e💧\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003e320 Pints Per Day\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eIndustrial moisture removal sized for mid-size flowering and veg rooms.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🌀\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003e775 CFM Airflow\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eStrong circulation moves humid air through the coils for faster, more even drying.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🔩\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eNo Hang Kit Needed\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eBuilt-in rivet nuts accept standard 3\/8\" threaded rod, cutting material cost and install time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🎛️\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eOnboard Digital Control\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eSet RH, read error codes, and connect a remote controller through the 24VAC terminal block.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🏗️\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eFlexible Installation\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eSuspended, freestanding, or ducted, with a removable plug for hardwired applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-card\"\u003e\n\u003cspan style=\"font-size: 2.5em; line-height: 1; color: #2c5530;\"\u003e🇺🇸\u003c\/span\u003e\u003ch5 style=\"font-size:1.1em;font-weight:bold;color:#333;margin:0.75rem 0 0.5rem 0;\"\u003eBuilt in the USA\u003c\/h5\u003e\n\u003cp style=\"font-size:0.95em;line-height:1.6;color:#555;margin:0;\"\u003eDesigned and assembled in Wisconsin, ETL listed, with a removable side panel for easy service.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch4\u003eWhat's Included\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAnden A321 V1 Dehumidifier\u003c\/li\u003e\n\u003cli\u003eLeveling feet\u003c\/li\u003e\n\u003cli\u003eCondensate hose\u003c\/li\u003e\n\u003cli\u003eBarb fitting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 style=\"margin-bottom: 0;\"\u003eSpecifications\u003c\/h4\u003e\u003cstyle\u003e.styled-spec-container{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;border:1px solid #eee;border-radius:8px;margin-bottom:1em;}.styled-spec-table{width:100%;border-collapse:collapse;}.styled-spec-table thead{background-color:#f8f8f8;}.styled-spec-table th,.styled-spec-table td{padding:12px 15px;text-align:left;vertical-align:top;}.styled-spec-table th{font-weight:bold;color:#333;border-bottom:2px solid #ccc;}.styled-spec-table td{border-bottom:1px solid #eee;}.styled-spec-table tbody td:first-child{font-weight:500;color:#444;}.styled-spec-table tbody tr:last-child td{border-bottom:none;}\u003c\/style\u003e\u003cdiv class=\"styled-spec-container\"\u003e\u003ctable class=\"styled-spec-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e320 pints\/day @ 80°F, 60% RH\u003cbr\u003e233 pints\/day @ 75°F, 50% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Factor\u003c\/td\u003e\n\u003ctd\u003e6.8 pints\/kWh (3.2 L\/kWh) @ 80°F, 60% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003e775 CFM @ 0.0\" WG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase \/ Frequency\u003c\/td\u003e\n\u003ctd\u003e208-240V, Single Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1,960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003eNEMA 6-15P, 6 ft. (removable for hardwiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ MOP\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e56°F \/ 40% RH to 95°F \/ 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOnboard digital interface with low-voltage terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Filter\u003c\/td\u003e\n\u003ctd\u003eMERV-13, 20\" × 22\" × 2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR454B, 62 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4\" FNPT (P-trap required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e32.9\" × 24.6\" × 23.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e178 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch4\u003eInstallation Options\u003c\/h4\u003e\u003cdiv\u003e\u003cp\u003eEvery grow room has its own constraints, from low ceilings to crowded floors. The Anden A321 V1 installs three ways, so you can put it where it does the most good.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin: 20px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n\u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_1.png?v=1792684234\" alt=\"Anden A321 V1 Dehumidifier suspended from ceiling with threaded rods\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\u003c\/div\u003e\n\u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eSuspended\u003c\/h5\u003e\n\u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eHangs overhead to keep floor space open for plants and carts.\u003c\/p\u003e\n\u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n\u003cli\u003eBuilt-in threaded inserts accept 3\/8\" threaded rod\u003c\/li\u003e\n\u003cli\u003eNo separate hang kit required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n\u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_2.png?v=1792684235\" alt=\"Anden A321 V1 Dehumidifier freestanding on a raised platform\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\u003c\/div\u003e\n\u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eFreestanding\u003c\/h5\u003e\n\u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eOperates on the floor inside the cultivation room.\u003c\/p\u003e\n\u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n\u003cli\u003eIncluded leveling feet steady the unit on uneven floors\u003c\/li\u003e\n\u003cli\u003eRaise the base 6\" so a P-trap fits below the drain\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 calc(33.333% - 14px); min-width: 260px; display: flex; flex-direction: column; text-align: center;\"\u003e\n\u003cdiv style=\"height: 240px; display: flex; align-items: center; justify-content: center; margin-bottom: 15px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_3.png?v=1792684234\" alt=\"Anden A321 V1 Dehumidifier with inlet and outlet duct connections\" style=\"max-width: 100%; max-height: 100%; width: auto; height: auto; object-fit: contain;\"\u003e\u003c\/div\u003e\n\u003ch5 style=\"font-weight: bold; margin: 0 0 10px 0; font-size: 1.1em;\"\u003eInlet and Outlet Ducted\u003c\/h5\u003e\n\u003cp style=\"font-size: 0.95em; line-height: 1.6; margin: 0 0 10px 0; min-height: 3.2em;\"\u003eSits in a separate room and connects to the grow space through ducts.\u003c\/p\u003e\n\u003cul style=\"text-align: left; font-size: 0.95em; line-height: 1.6; margin: 0;\"\u003e\n\u003cli\u003eIdeal for rooms with limited space\u003c\/li\u003e\n\u003cli\u003eOptional duct kit sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch4\u003eSupport \u0026amp; Manuals\u003c\/h4\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-Manual-A321.pdf?v=1792684158\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eInstallation \u0026amp; Operating Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-Spec-Sheet-A321v1.pdf?v=1792684156\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eA321 V1 Spec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden-A320-to-321-Transition.pdf?v=1792684158\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-flex; align-items: center; background-color: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 12px 18px; text-decoration: none; color: #333; transition: background-color 0.3s ease, box-shadow 0.3s ease;\"\u003e\u003cspan style=\"font-size: 1.5em; margin-right: 12px;\"\u003e📄\u003c\/span\u003e\u003cspan style=\"font-weight: bold;\"\u003eA320 to A321 Transition Guide\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003cp\u003eThe Anden A321 V1 Dehumidifier is covered by a 3-year limited manufacturer warranty from the original date of purchase.\u003c\/p\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cdiv class=\"faq-container\"\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eHow big a room can the A321 V1 handle?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe A321 V1 removes up to 320 pints per day at 80°F and 60% RH, and 233 pints per day at 75°F and 50% RH. Room size depends on plant count, watering volume, and air infiltration, so size the unit to your daily moisture load rather than square footage alone. The room should have a minimum floor area of 28 m² (about 300 sq ft).\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat outlet and circuit does the A321 V1 need?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe A321 V1 ships with a 6 ft. NEMA 6-15P cord for a 208-240V single-phase receptacle, with an MCA of 15 A and an MOP of 25 A. A GFCI-protected circuit is required. For hardwiring, the cord can be removed and replaced with the jumper wires from the packed parts kit, along with a field-installed disconnect.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eHow do I hang the A321 V1?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThread four 3\/8\" rods into the built-in rivet nuts on top of the unit, which are spaced 16.6\" × 22.2\" apart. Engage each rod at least 1.5\" but no more than 2.5\", because inserting too far can damage the unit. Never hang it from the sides or ends, and mount it so the drain outlet sits 6.75\" above the floor drain.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eCan the A321 V1 directly replace my Anden A320?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe A321 V1 is similar in size but not a drop-in replacement. It uses a 15A cord instead of the A320's 20A cord, has different hanging points, and does not work directly with the A77 controller. It must also be placed last in any daisy chain that includes A320 units. The A320 to A321 Transition Guide covers each of these changes, including how to reuse your A320 cord.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eCan I duct the A321 V1 from another room?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eYes. An optional duct kit, sold separately, connects the intake and exhaust to the grow room. Keep total static pressure below 0.25\" WG, and duct supply and return air directly to the space rather than through open areas like drop ceilings.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhich remote controllers work with the A321 V1?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe 24VAC terminal block works with Anden's DEH 3000R and QA76 controls, or any dry-contact controller rated for a 24VAC signal, such as TrolMaster. If you also need to increase humidity in drier environments, you can integrate the \u003ca href=\"\/products\/anden-as35fp-medium-capacity-steam-humidifier\"\u003eAnden AS35FP Medium-Capacity Steam Humidifier\u003c\/a\u003e. Press the Terminal Control button after wiring so the unit follows the external signal. Up to six units can run from one control on a daisy chain.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eHow do I know when to change the filter?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe filter light turns on after 2,000 hours of fan run time, or sooner if the pressure switch senses a clogged filter. Replace it with a 20\" × 22\" × 2\" MERV-13 filter, then hold the Filter Reset button to restart the timer.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e\n\u003cspan\u003eWhat does the A321 V1 warranty include?\u003c\/span\u003e\u003cspan class=\"faq-icon\"\u003e+\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003e\u003cdiv\u003e\u003cp\u003eThe 3-year limited warranty provides 1 year of full coverage, plus 2 additional years of parts replacement on the condenser, evaporator, and compressor. Warranty claims start with a call to the factory at 1-877-420-1330 for authorization.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Anden","offers":[{"title":"Default Title","offer_id":52771671802072,"sku":"A321V1","price":4499.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1383\/1731\/files\/Anden_A321_V1_Dehumidifer_4.png?v=1792684242","url":"https:\/\/trimleaf.com\/products\/anden-a321-v1-mid-size-grow-dehumidifier-320-ppd-240v","provider":"Trimleaf","version":"1.0","type":"link"}